Contact Us
For price and delivery today
The heart of the LNG Vaporizer Assembly is the well-known HPR-2 Series heated pressure control valve.
This unit has been used in many successful applications requiring heating of a process stream sample prior to analysis to prevent freeze up or for vaporization.
The HPR-2 is a modularized unit consisting of a heated section and pressure control section.
A field demonstration has now shown this vaporizer assembly to be serviceable in the vaporization of LNG product for analytical purposes and that homogeneous samples can be obtained under steady state operating conditions.
The HPR-2 pressure control valve is contained in a painted, insulated sheet metal enclosure and combined with an insulated input line plus a pressure gauge and relief valve. The heater section of the electric version is equipped with a thermostat for temperature control and is constructed to meet standard Division 1 Electrical Code requirements.
For price and delivery today
Applications
CONSTRUCTION | 316L stainless steel |
OUTLET PRESSURES | 0–10, 0–25, 0–50, 0–100, 0–250, and 0–500 psig |
INLET PRESSURE | up to 3600 psig at 380° F (193° C) |
OPERATING TEMPERATURE | up to 500° F (260° C) |
INLET CONNECTIONS | 1⁄8˝ FNPT |
OUTLET CONNECTIONS | ¼˝ FNPT | HEATING CAPACITY RANGES (IN WATTS) | 40, 50, 100, and 150 |
CERTIFICATIONS | CSA certifi cation # LR-82566-5 ATEX Directive 2014/34/EU Certifi cation # TRL03ATEX11001X |
Flow Formulas
Copyright © 2024 — Crane Co., Crane Instrumentation & Sampling PFT Corp. All Rights Reserved. -> IMPORTANT: This site uses cookies to enhance your user experience. Continued use of this site indicates your consent.